As the professional manufacturer, ZIKAI® would like to provide you MV Ring Main Unit. And ZIKAI® will offer you the best after-sale service and timely delivery.
You can rest assured to buy MV Ring Main Unit from our factory and we will offer you the best after-sale service and timely delivery. GTHXGN-12 High voltage solid insulated ring network cabinet is a vacuum switchgear with fully insulated, fully enclosed and maintenance-free features. It uses high-performance epoxy resin material, all high-voltage live components are integrated casting molding, perfect integration of vacuum interruptor, main electrical path and insulation support structure, forming a compact and robust whole.
Zi Kai MV ring main unit product parameters:
item
unit
parameters
routine
Rated voltage
kV
12
Rated frequency
HZ
50
Power frequency withstand voltage
kV/min
42/48
Lightning impulse voltage
kV
75/85
Duration of ignition
S
≥0.5
Primary component protection class (metering cabinet
IP67
Except)
IP4X
Cabinet protection level
IP2X
Class of compartment protection
Operating supply voltage
V
DC24、48、110、220
AC110、220
Bus system
A
630(1250)
Rated current
kA/s
20/4(25/4)
Rated short-time withstand current
kA
50(63)
Rated peak withstand current
kA
50
Rated peak withstand current
Load switching unit
A
630
Rated current
kA
50
Rated short-circuit closing current
kA/s
20/4
Rated short-time withstand current
time
Load switch mechanical life
time
E3
Load switch electrical life
PC
≤5
Partial discharge
Circuit breaker unit
A
630(1250)
Rated current
kA
20(25)
item
unit
parameters
Rated short-circuit closing current
kA
50(63)
Rated short-time withstand current
kA/S
20/4(25/4)
Mechanical life of circuit breaker
time
20000
Circuit breaker electrical life
time
E2
Rated operating sequence
0-0.3s-CO-180s-CO
Partial discharge
PC
≤5
Load switch -
Fuse combination electrical unit
A
200
Rated current (Max.)
kA
31.5
Rated short-circuit breaking current
kA
80
Rated short-circuit closing current
PC
3150
Partial discharge
Disconnecting switch
A
630/1250
Rated current
kA
20/25
Rated short-time withstand current
S
4
Rated short duration
kA
50/63
Rated peak withstand current
time
3000
Mechanical life
Ground switch
A
630/1250
Rated current
kA
20/25
Rated short-time withstand current
S
4
Rated short duration
kA
50/63
Rated peak withstand current
kA
50
Rated short circuit closing current (peak)
time
2
Rated short circuit closing current number
time
3000
Zi Kai MV ring main unit Different configuration Outline
PT cabinet with load switch (fully insulated type)
Standard configuration
◆630A insulated bus ◆ Load grounding switch
◆ Load grounding switch operating mechanism
◆ Load/ground switch
◆ The outlet bushing is located in the front horizontal position, and the 630A front cable head is connected
◆ Live indicator and nuclear phase hole integration, in line with ISO61958 standard
◆ Solid insulated voltage transformer
◆ Elbow joint (with cable)
◆ Voltage transformer protection breaker
◆ Ground busbar
◆ Meet the five anti-interlock
Optional configuration ◆ Heater ◆ Voltmeter
Breaker cabinet
Standard configuration
◆630, 1250A insulated bus
◆ Vacuum circuit breaker
◆ Vacuum circuit breaker operating mechanism
◆ Isolated ground switch
◆ Isolation/grounding switch operating mechanism
◆ Circuit breaker and ground switch mechanical interlock
◆ Circuit breaker and ground switch have independent position display
◆ The outlet bushing is located in the front horizontal position, and the front cable head is connected
◆ Live indicator and nuclear phase hole integration, in line with ISO61958 standard
◆ Ground busbar
◆ Microcomputer protection device
◆ Meet the five anti-interlock
Optional configuration
◆ Auxiliary contact ◆ Program lock
◆ Heater
◆ Rear arrester
◆ Rear cable head
◆ Incoming line live ground lock
◆ Ground fault indicator
◆ Bushing type current transformer and ammeter, active power meter, reactive power meter
Circuit breaker busbar
Standard configuration
◆630A, 1250A insulated bus
◆ Vacuum circuit breaker
◆ Vacuum circuit breaker operating mechanism
◆ Isolation/grounding switch
◆ Isolation/grounding switch operating mechanism
◆ Circuit breaker and ground switch mechanical interlock
◆ Circuit breaker and ground switch have independent position display
◆ The outlet sleeve is located in the front horizontal position, and the front cable head (with cable)
◆ Live indicator and nuclear phase hole integration, in line with ISO61958 standard
◆ Ground busbar
◆ Microcomputer protection device
◆ Meet the five anti-interlock
Optional configuration
◆ Auxiliary contact ◆ Program lock
◆ Heater
◆ Rear arrester
◆ Rear cable head
◆ Incoming line live ground lock
◆ Ground fault indicator
◆ Bushing type current transformer and ammeter, active power meter, reactive power meter
Hoist tank
Standard configuration
◆630A, 1250A insulated bus
◆ The outlet sleeve is located in the front horizontal position, and the front cable head (with cable)
◆ Live indicator and nuclear phase hole integration, in line with ISO61958 standard
◆ Ground busbar
Optional configuration ◆ Heater
◆ Rear arrester
◆ Rear cable head
◆ Ground fault indicator
◆ Bushing type current transformer and ammeter, active power meter, reactive power meter
Zi Kai MV ring main unit Note
Inspection before use: Before the ring network unit is used, the following checks must be carried out for personal and equipment safety
Check whether the main circuit and the ground circuit are correctly connected.
Check whether the mechanical interlock is correct and reliable.
Check whether the load switch and ground switch in the ring network unit are operated flexibly and correctly.
Check the high voltage cable connection is correct and reliable.
Zi Kai MV ring main unit Details
certificates
Standard
◇Q/GDW730-2012 "12kV solid insulation ring network cabinet technical conditions"
◇GB1984 "AC high voltage Circuit breaker"
◇GB38043.6kV-40kV "AC high voltage load switch"
◇GB1958 "AC High voltage isolation switch and ground switch"
◇GB4208 "Shell protection level IP Code"
◇GB 16926 High voltage AC load switch-fuse combination appliance
◇GB/T15166.2 High voltage AC circuit breaker - Part 2: Current limiting circuit
◇GB/T7354 "Partial Discharge Measurement"
◇GB/T11022 "High Voltage Switchgear and control equipment standards common technical conditions"
◇GB3906 "3.6-40.5kV AC metal enclosed switchgear and control equipment"
FAQ
1、What is your packaging standard?
Usually we use standard foam and carton packaging. If you have special requirements, we can also meet your requirements.
2、Why do you buy from us instead of other suppliers?
More than 10 years experience in design and manufacture of high voltage switchgear accessories. It is one of the largest star suppliers in the industry, and has won international and domestic praise, and has been shortlisted for the National Grid.
If you have any enquiry about quotation or cooperation, please feel free to email or use the following inquiry form. Our sales representative will contact you within 24 hours.
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies.
Privacy Policy