ZIKAI® is a proficient manufacturer and supplier of Gis Rmu Ring Main Unit Switchgear in China. The primary and secondary fusion ring cage is the fusion of the primary equipment and secondary equipment required by the ring cage, which integrates the ring cage body, high-precision sensors and secondary terminals. This fusion pursues reliability, miniaturization, platformization, versatility and economy, making the ring cage more effectively distribute, control and protect electric energy in the power system.
Zi Kai gis rmu ring main unit switchgearproductMain composition:
Station automation terminal DTU
Interval metering function
Distribution line loss collection module is configured to realize metering function (active power level 0.55, reactive power level 2).
Calculation of positive and negative active power quantity, four-quadrant reactive power quantity and power factor (resolution 0.01); It has the function of freezing metering data, including daily freezing and freezing data when the power direction changes。
Measuring function
Collect the three-phase voltage, current, active power, reactive power, power factor, frequency, zero sequence current and zero sequence voltage of each line.
Fault handling
It has the function of interphase fault detection and tripping between feeder lines, and the function of interphase fault information upload. Ground fault detection and fault information uploading capability with loop in loop out unit and all feeder intervals; With ground fault recording and communication upload function, ground recording more than 80 waves per week;
Data call
Support remote access to historical data, upload to the main station in the form of files;
Daily freezing capacity, electric energy, power, voltage, current fixed point data, voltage, current daily extreme value number。
Data storage
Cyclic storage, no loss of power; Store fixed point records and extreme value records for at least 31 days; Fixed-point data is generated at equal intervals 96 pieces per day, and extreme value records are generated 1 piece per day.
Plug and play
Support the plug-and-play function of the primary and secondary power distribution fusion device to the main power distribution station; The data model was modeled by IEC61850.
Remote parameter setting
Support distribution automation terminal key parameters standardized unified configuration and master station remote setting; Support distribution automation communication protocol standardization expansion.
Line loss acquisition module
Rated voltage
3x(100V/ √3); Specific voltage 3x(10kV/ √3)
Rated current
5A; Primary reference current 600A
Accuracy class
Active power level 0.5S, reactive power level 2
Pulse constant
20000imp/MWh; 20000imp/MVarh
Measurement and control capacity
Route 8
Structural form
2U electromagnetic (standard 19 ", rack mount)
Working power supply
DC24V; Power consumption is small F1W
Ring network cabinet three-phase PT
Voltage sensor
Rated voltage ratio
(10kV/ √3)/(100V/3
Accuracy class
Grade 0.5; Zero sequence 3P(2%~190Un)
Temperature range
-40℃~70℃
Partial discharge
≤20pC(1.2Um/ √3)
Load impedance
Terminal input impedance >10 MQ; Line loss acquisition module input impedance >10 MQ; Integrated impedance >5MO
Zi Kai gis rmu ring main unit switchgear Precautions for use
Check the shape, size and integrity of the ring cage before installation. Replace the ring cage if damaged. When connecting, standard products must be used to ensure stability and safety. Verify connection seal and pressure resistance before use. Avoid damage to the box during transportation and use to prolong life. Regular maintenance of the ring cage, timely repair or replacement, to ensure continuous operation.
Zi Kai gis rmu ring main unit switchgear Feature
Highly integrated:
The primary and secondary fusion ring cage integrates the functions of the primary side and the secondary side into one device, realizing the seamless integration of multiple functions such as power distribution, protection, control, and measurement.
This design reduces the number of interfaces between devices and reduces the probability of failure.
Intelligent management:
Equipped with telemetry, remote communication, remote control functions, operation and maintenance personnel can remotely monitor the operating status of the equipment, timely detection and treatment of potential problems.
Rich functional configuration:
In addition to the basic power distribution function, the primary and secondary fusion ring cage also has rich functions such as metering, interphase and ground fault handling, communication, and secondary power supply.
Zi Kai gis rmu ring main unit switchgear Details
certificates
FAQ
1、Are you a trading company or a direct manufacturer?
We are a professional factory with 10 years of industry experience, specializing in the manufacture of high and low voltage switchgear, substations, transformers, cable distribution boxes and all kinds of electrical equipment, including but not limited to vacuum circuit breakers, load break switches, etc. Our factory with its excellent product quality and professional service, won the State Grid Corporation of China excellent supplier title.
2、Why do you buy from us instead of other suppliers?
More than 10 years experience in design and manufacture of high voltage switchgear accessories. It is one of the largest star suppliers in the industry, and has won international and domestic praise, and has been shortlisted for the National Grid.
If you have any enquiry about quotation or cooperation, please feel free to email or use the following inquiry form. Our sales representative will contact you within 24 hours.
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies.
Privacy Policy